Intelligent control.

Switch load, valves and equipment on your own rules: a tariff, a schedule, a demand limit, or a live reading from another sensor.

1 · What it is for

Intelligent control is where the platform stops watching and starts acting. A control switch or valve controller fires on a rule you set, closing the loop from a reading to an action with no one in the middle. It is the same platform and the same rules, driving an output instead of raising an alert.

2 · How the rules work

2.1 · What fires it

Switch on a weekly schedule, in line with loadshedding, by time-of-use tariff, on a live reading from a sensor such as temperature or level, or by hand.

2.2 · What it drives

The Airswitch switches devices directly, and larger loads through external contactors, in AC or DC. Valve controllers open and close valves on a schedule or a reading.

3 · Use cases

  • Loadshedding. Shed non-critical load ahead of a stage and restore it after.
  • Tariff switching. Run a load only in the cheaper time-of-use blocks.
  • Irrigation. Open a valve when soil moisture drops below its band.
  • Temperature control. Cut a heater or fan once a reading reaches its limit.
  • Level control. Hold a tank or pump within a level band.

4 · The hardware

Control runs on the Airswitch and valve controllers. The Airswitch comes in LoRa or LTE versions and in AC and DC models, driving larger loads through external contactors.

5 · Good to know

Control acts; monitoring watches. A rule can chain off any sensor reading, so control and sensing work together. Safety-critical interlocks belong in hardwired protection systems, not in a wireless control rule, and, like everything else, control is scoped to your access.

Common questions

What can trigger a switch?

A schedule, loadshedding, a time-of-use tariff, a live reading from a sensor, or a manual command.

What can it switch?

Devices directly, larger loads through external contactors, and valves through a valve controller.

Can it act on another sensor’s reading?

Yes. A rule can fire on a live reading such as temperature or level, closing the loop from sensing to action.

What hardware does it need?

The Airswitch for switching, and valve controllers for valves.

Hardware
The devices that do the switching.
Control switchesConnectivity
Reports & tools
The alerting layer alongside control.
Triggers & alerts
What we measure
The readings a control rule can act on.
Air temperatureSoil moistureLevel